PS200 34.375MHz-2.7GHZ UV RF Vector Impedance ANT SWR Antenna Analyzer
UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester 34.375MHz - 2.7GHz is Pro Tool to test our DIY Antenna for DJI Phantom Inspire MAVIC. It is a must tool for all DIY DJI Phantom Inspire MAVIC Pilot.
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
- The default boot into single-point measurement interface.
- The default boot into single-point measurement interface.
Specifications:
- Model: PS200
- Working currency 34.375MHz~2700MHz
- Stepped frequency 1kHz
- Display 2.4cun TFT trdp
- Resolution ratio 320*240(QVGA)
- Battery capacity: 2000mAH(7.4Wh)
- Power consumption <1.5W
- Charge current 400mA
- Charge port USB
- Auto power off can be set 5-60minutes
- Measured parameters resistence reactance standing wave s11
- Resolution ratio 4 number
- Frequency accuracy about 5ppm
- Connector SMA-K
- Impedance measurement range: 0.1~1000
- Standing wave measurement range:1.000~65
- S11(dB)measurement range: 0dB~-60dB
- Working temperature:0~40 degree
- Atmospheric pressure:860hPa~1060hPa
- Model: PS200
- Working currency 34.375MHz~2700MHz
- Stepped frequency 1kHz
- Display 2.4cun TFT trdp
- Resolution ratio 320*240(QVGA)
- Battery capacity: 2000mAH(7.4Wh)
- Power consumption <1.5W
- Charge current 400mA
- Charge port USB
- Auto power off can be set 5-60minutes
- Measured parameters resistence reactance standing wave s11
- Resolution ratio 4 number
- Frequency accuracy about 5ppm
- Connector SMA-K
- Impedance measurement range: 0.1~1000
- Standing wave measurement range:1.000~65
- S11(dB)measurement range: 0dB~-60dB
- Working temperature:0~40 degree
- Atmospheric pressure:860hPa~1060hPa
Advice When Using:
- In order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
- Try to use good quality RF cable and connectors.
- Calibrated cable marked to the next may not need to calibrate and direct use.
- Test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
- Measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
- If the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.
- In order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
- Try to use good quality RF cable and connectors.
- Calibrated cable marked to the next may not need to calibrate and direct use.
- Test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
- Measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
- If the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.
Notes:
1.The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2. For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
1.The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
2. For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Package include:
1 x PS200 UV RF Vector Impedance ANT SWR Antenna Analyzer Meter
1 x Charge cable
1 x PS200 UV RF Vector Impedance ANT SWR Antenna Analyzer Meter
1 x Charge cable