N1201SA UV RF Vector Impedance ANT SWR Antenna Analyzer Meter 35MHZ-2.7GHZ

RFID Antenna Analyzer Meter Tester 35MHZ-2.7GHZ N1201SA plus N1201SA+ UV RF Vector Impedance ANT SWR

Features:

Operating Frequency :35MHz-2.7GHz

Frequency Step :1kHz

monitor dispaly :2.4-inch TFT Resolution 320 × 240 (QVGA)

battery capacity:  2000mAH (7.4Wh)

Power consumption : <1.5W

Charge Current: 400mA

Charging Interface: USB (only temporarily as the charging interface, data transmission not yet open)

Automatic shut-down( You can set  open, 5 minutes to 60 minutes Optional)

N1201SA GSM Antenna analyzer Specifications

Measurement parameters:

impedance : 0.1Ω ~ 1000Ω (impedance absolute value)

SWR: 1.000 to 65

s11 (dB):  0dB ~ -60dB

Resolution

impedance : 

SWR : 

s11(DB / °):  0.1 dB / 5 ° (0dB ~ -10dB)

1 dB / 10 ° (-10dB ~ -20dB)

5dB / 20 ° (-20dB ~ -40dB)

Directionality  :<35dB (140MHz ~ 2GHz after calibration), <30dB (2GHz ~ 2.7GHz)

Scan Points: 280

Output Level: -18dBm

Operating temperature: 0 ~ 40degree

Atmospheric pressure: 860hPa ~ 1060hPa

physical dimension

Height 120mm * Width 860mm * 300mm thick

Minimum impedance measurement resolution 0.001Ω,

This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

The default boot into single-point measurement interface.

Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.

Startup and shutdown

Hold down the CTRL key off press the power switch button.

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

Some recommend the use of the instrument

1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

2, try to use good quality RF cable and connectors.

3, calibrated cable marked to the next may not need to calibrate and direct use.

4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.

  • Frequency 35MHz~2700MHz
  • Spacing 1kHz
  • Display 2.4inch TFT Pixel 320×240(QVGA)
  • Battery 2000mAH(7.4Wh)
  • Power dissipation <1.5W
  • Charging current 400mA
  • Charging port USB(For charging only)
  • Auto Power Off Adjustable(Always on,5mins~60min)
  • Measure facts resistance/reactance/SWR/s11
  • Resolution ratio 4bits effective digits
  • Frequency accuracy ±5ppm
  • Connector SMA-K
  • Measuring range impedance   0.1Ω~1000Ω(Absolute value of impedance)

SWR              1.000~65

s11(dB)         0dB~-60dB

  • Error impedance    

(single point measurement)       SWR               

s11 dB/° 0.1 dB /5° (0dB~-10dB)

1 dB /10° (-10dB~-20dB)

5dB/20° (-20dB~-40dB)

  • Directivity <35dB(140MHz~2GHz After calibration)

<30dB(2GHz~2.7GHz)

  • Scan Points 280
  • Output level -18dBm
  • Working temperature 0~40
  • Atmospheric pressure 860hPa~1060hPa
  • Dimension 116mm*85mm*33mm

Each Unit Package Contain:

1 X N1201SA GSM Antenna analyzer

1 X Power Cable

1 X English manual